- Get from Mellanox the appropriate version of the firmware to start with. For our ConnectX2 NICs (as of December 2012) this file is in
~ouster/samba/mellanox/fw-ConnectX2-rel.mlx
. This file needs to be combined with an appropriate .ini file. First, fetch the existing .ini file from the NIC:
Code Block flint
-d
dc > mt26428.ini/dev/mst/mt26428_pci_cr0
flint -dNo Format dc > MT_0DD0120009.ini
Check
/dev/mst
to verify the file name there. In this case the .ini file is named after theboard_id
printed byibv_devinfo
(we have two different board ids, which have different .ini files (though they use the same .mlx file).Edit the .ini file to add a new
qp_minimal_timeout_val
parameter with a value of zero. It goes in the HCA section, like this:No Format [HCA] hca_header_device_id = 0x673c hca_header_subsystem_id = 0x0018 dpdp_en = true eth_xfi_en = true mdio_en_port1 = 0 qp_minimal_timeout_val = 0
- Generate a new image from the .mlx file and the .ini file:
mlxburn -fw fw-ConnectX2-rel.mlx -conf MT_0DD0120009.ini -wrimage MT_0DD0120009.bin
- Upload the image into the NIC:
flint -d /dev/mst/mt26428_pci_cr0
dc > mt26428.ini
...
-i MT_0DD0120009.bin -y b
- Beware: if different NICs have different board ids, they will need different .ini files, and they may need different .mlx files (ask Mellanox for help).